Testing Control unit, EEPROM processor 1 fault Flash code: 3x long, 2x short Fault indication: Fault is indicated by the EDC indicator lamp coming on continuously Fault path: Processor 1 in control unit faulty (EEPROM 1) Possible cause: Control unit faulty, EOL programming not completed (voltage supply interrup- ted) Effect of fault: Engine is shut off Engine will not start 53 Test Measurement Corrective measures Power supply No further testing necessary – Complete EOL program- ming, clear fault codes – Replace control unit (only di- sconnect control unit once the current is switched off) Control unit