STRUCTURE AND FUNCTION ELECTRONIC CONTROL SYSTEM Lifting operation (L/O) mode Matching point in lifting operation mode: 60% partial output point When the lifting operation mode is selected, the engine speed is automatically lowered to the partial position. In this condition, control is car- ried out in the same way as for the general op- eration, finishing operation, and breaker opera- tion modes to match the load on the pump. In this way, the fuel consumption is reduced and the fine control ability is improved. Power maximizing mode Matching point in power max. mode: Rated out- put point When the pump load increases, the engine speed drops.
When this happens, the pump discharge is re- duced to prevent the engine speed from going down and to ensure that the engine is used at near the rated output point. 10-142 Model Mode PC210-6K PC240-6K Lifting operation (L/O) 57 kW/1,500 rpm 76 HP/1,500 rpm 76 kW/1,500 rpm 102 HP/1,500 rpm Model Mode PC210-6K PC240-6K POWER MAX. 99 kW/2,000 rpm 133 HP/2,000 rpm 117 kW/2,000 rpm 158 HP/2,000 rpm