Hydraulic Brake System, Bosch 42.15 Troubleshooting No No No No Is the leak at the backup pump? Is the leak at the interface between adapter and booster housing or backup pump? See Figure 11. The problem is probably with the booster. Re− place booster. See Subject 150. Is flow switch leaking? Is the leak at the inlet port? Yes Yes Yes Yes The problem is probably with the flow switch O−ring. Replace the O−ring. See Subject 170. The problem is probably with the inlet fitting O−ring. Re− place the O−ring. The problem is probably with the backup pump. Re− place the pump. Clean and examine sealing surfaces and seal grooves of the adapter, backup pump, and booster housing.
The problem is probably with the seals between the backup pump adapter and booster housing. Replace the seals. Yes Are surfaces and grooves flat and free of damage? No Replace the damaged component. 03/21/2003 f040630 Fig. 12, Flow Chart: Hydraulic System Leakage (cont.) Business Class M2 Workshop Manual, Supplement 17, March 2010 300/11