Air Management Unit 42.19 Troubleshooting Pressure Protection Valve Specs No. of Delivery Ports (External) Part Number Open psi (kPa) Closed psi (kPa) 12-18200-255 2 55 ±8 (379 ±55 kPa) 45 ±5 (310 ±34) 12-18200-285 2 85 ±8 (586 ±55 kPa) 67 ±5 (462 ±34) 12-18200-355 3 55 ±8 (379 ±55 kPa) 45 ±5 (310 ±34) 12-18200-385 3 85 ±8 (586 ±55 kPa) 67 ±5 (462 ±34) A12-19772-255 2 55 ±8 (379 ±55 kPa) 45 ±5 (310 ±34) A12-19772-285 3 85 ±8 (586 ±55 kPa) 67 ±5 (462 ±34) A12-19772-355 2 55 ±8 (379 ±55 kPa) 45 ±5 (310 ±34) A12-19772-385 3 85 ±8 (586 ±55 kPa) 67 ±5 (462 ±34) Table 8, Pressure Protection Valve Specs Test 2.3 Connect an accurate pressure gauge to the secondary air tank.

Perform the followings pressure protection valve test to determine if the pressure protection valve module is functioning correctly. If any part of the test fails, replace the module. Start the engine and build air to maximum air pressure. Shut the engine off. 2.4 Open the valve installed on the delivery port of the module. When air stops flowing through the valve, observe the pressure gauge on the secondary air tank. The pressure should not fall below approxi- mately the closing pressure listed in Table8 . 1. Test for supply pressure drop protection. 1.1 Drain the air tanks. 1.2 Disconnect one of the delivery ports on the face of the module and connect an accurate pressure gauge.

1.3 Connect an accurate pressure gauge to the secondary air tank. 3. Test for opening pressure. 3.1 Drain the air tanks. 1.4 Start the engine and build air to maximum air pressure. Shut the engine off. 3.2 Disconnect one of the delivery ports on the face of the module and connect an accurate pressure gauge. 1.5 Drain the secondary air tank while watch- ing the gauges. The pressure on the deliv- ery port of the pressure protection valve module should stop falling at approxi- mately the closing pressure in Table8 , while the pressure on the secondary tank gauge continues to fall to zero. 3.3 Connect an accurate pressure gauge to the secondary air tank.

3.4 Start the engine and observe the gauges. The gauge on the delivery port of the module should remain at 0 psi (kPa) until the pressure in the secondary air tank pressure gauge reaches approximately the opening pressure listed in Table8 . 2. Test for delivery pressure drop protection. 2.1 Drain the air tanks. 2.2 Disconnect one of the delivery ports on the face of the module and connect a valve (use fittings and airline as neces- sary). Close the valve. Business Class M2 Workshop Manual, Supplement 9, March 2006 300/8