Air Management Unit 42.19 Troubleshooting Solenoid Valves General Information This helps during manufacturing to match colored air lines to the correct solenoid valve. Other than that, they are functionally the same. Normally closed sole- noid valves have a black cover, and normally open solenoid valves have a natural (light beige) colored cover. Each solenoid valve has an internal pressure switch that monitors delivery pressure. Solenoid valves with part numbers 12-18208-XXX have a di- ode wired in parallel with the pressure switch. All so- lenoid valves have a diode wired in parallel with the solenoid coil to prevent voltage spikes.
Solenoid Valve Electrical Pin and Functional Tests The solenoid valves control chassis components such as the fifth-wheel slide, rear suspension dump, inter-axle lock, diff-lock, end-of-frame air option, transfer case, and other ON-OFF air options. Sole- noid valves are supplied with pressure protected sec- ondary air. Therefore, they are always positioned to the left of the pressure protection valves on the air management unit (AMU). There are two variations of the solenoid valve, one is normally closed and the other is normally open. The normally closed sole- noids come with various delivery port collar colors. Conditions Test Point Good Result If Test Fails:
Solenoid Coil Resistance and Diode Check * ·Key OFF, Engine OFF. Coil Resistance and Diode Check: Measured between pin C and D (switch side). Then, reverse test leads and check again. Approx. 16 ohms with leads both ways. Replace solenoid valve. ·Solenoid valve connector disconnected. NOTE: If result was much greater than 16 ohms one way and 0 ohms with the leads reversed, then the coil is open. If the result was 0 ohms both ways, then the diode or coil is shorted. There is no way to specifically check the internal diode. * NOTE: The solenoid has an internal diode wired in parallel with the coil.
Table 9, Solenoid Coil Resistance and Diode Check Solenoid Valve Pressure Switch Diode Test Conditions Test Point Good Result If Test Fails: ·Drain air tanks. ·Key OFF, Engine OFF. Resistance Check (or diode test if meter is capable) With the leads connected one way the meter should read resistance (value not important), then when the leads are reversed the reading should be infinite or OL. Replace solenoid valve ·Solenoid valve connector disconnected. Measured between pin A and B (switch side). Then, reverse test leads and check again. Applies to part numbers 12- 18208-XXX: For all other part numbers: Skip this step. NOTE:
If the meter reads 0 ohms both ways, then either the switch is stuck closed or the diode is shorted. If the meter reads OL both ways, the diode is open. Table 10, Solenoid Valve Pressure Switch Diode Test Business Class M2 Workshop Manual, Supplement 9, March 2006 300/9