Air Management Unit 42.19 Troubleshooting Solenoid Valve Functional Test Conditions Test Point Good Result If Test Fails: ·Drain the air tanks. ·Solenoid valve connector disconnected. Solenoid Valve Functional Test: For Normally Closed Valves: Before connecting the jumper wires, the pressure gauge should read zero pressure. Replace solenoid valve. Using a fused jumper wire, connect solenoid pin C (solenoid valve side) to the positive battery post. Using another jumper wire, connect solenoid pin D (solenoid valve side) to ground. ·Disconnect the air line to the external delivery port on the solenoid valve and connect an accurate pressure gauge in its place.
The solenoid should switch on and deliver air to the external delivery port (pressure should read on the gauge). ·Start the engine and build air to full pressure. Shut the engine OFF. Do not reverse the polarity of the solenoid coil, damage to the internal diode may result. For Normally Open Valves: ·Key OFF, Engine OFF Before connecting the jumper wires, the pressure gauge should read pressure (55 or 85 psi [379 or 586 kPa] depending on upstream pressure protection valve). The solenoid should switch on and exhaust air from the external delivery port (pressure should read zero on the gauge).
Table 11, Solenoid Valve Functional Test Solenoid Valve Pressure Switch Functional Test (for normally closed valves only) Conditions Test Point Good Result If Test Fails: ·Drain the air tanks. ·Solenoid valve connector disconnected. Solenoid Valve Pressure Switch Functional Test: With the Solenoid Energized: The resistance, with the leads both ways, should be less than 1 ohm, and the pressure gauge should read 55 psi (379 kPa) or 85 psi (586 kPa), depending on the upstream pressure protection valve. Replace solenoid valve. Using a fused jumper wire, connect solenoid pin C (solenoid valve side) to the positive battery post.
Using another jumper wire, connect solenoid pin D (solenoid valve side) to ground. ·Disconnect the air line to the external delivery port on the solenoid valve and connect an accurate pressure gauge in its place. ·Start the engine and build air to full pressure. Shut the engine OFF. Do not reverse the polarity of the solenoid coil, damage to the internal diode may result. With the Solenoid De- energized: ·Key OFF, Engine OFF The resistance, with the leads both ways, should be more than 1 ohm, and the pressure gauge should read 0 psi. Once the solenoid has been energized, measure the resistance across pins A and B, then reverse the leads and check again. NOTE:
Solenoid valves with a part number 12-18208-XXX have a diode wired in parallel with the pressure switch. Table 12, Solenoid Valve Pressure Switch Functional Test (for normally closed valves only) Business Class M2 Workshop Manual, Supplement 9, March 2006 300/10