Air Management Unit 42.19 Troubleshooting Solenoid Valve Pressure Switch Functional Test (for normally open valves only) Conditions Test Point Good Result If Test Fails: ·Drain the air tanks. ·Solenoid valve connector disconnected. Solenoid Valve Pressure Switch Functional Test: With the Solenoid Energized: The resistance with the leads both ways should be more than 1 ohm and the pressure gauge should read 0 psi. Replace solenoid valve. Using a fused jumper wire, connect solenoid pin C (solenoid valve side) to the positive battery post. Using another jumper wire, connect solenoid pin D (solenoid valve side) to ground.
·Disconnect the air line to the external delivery port on the solenoid valve and connect an accurate pressure gauge in its place. With the solenoid De- energized: The resistance with the leads both ways should be less than 1 ohm and the pressure gauge should read 55 psi or 85 psi, depending on upstream pressure protection valve. ·Start the engine and build air to full pressure. Shut the engine OFF. Do not reverse the polarity of the solenoid coil, damage to the internal diode may result. ·Key OFF, Engine OFF Once the solenoid has been energized, measure the resistance across pins A and B, then reverse the leads and check again. Note:
Solenoid valves with a part number 12-18208-XXX have a diode wired in parallel with the pressure switch. Then disconnect the jumpers and measure the resistance across pins A and B again, then reverse the leads and check again. Table 13, Solenoid Valve Pressure Switch Functional Test (for normally open valves only) Pressure Regulator Module General Information justable and non-adjustable pressure regulator valves. These valves do not have internal supply and delivery ports. The body color of all pressure regula- tors modules is natural (light beige). The delivery port collar colors vary depending on pressure setting. See Table 14 .
The pressure regulator module limits the pressure delivered from the valve to some level depending on its setting. Any pressure below this level will be nearly equal to the supply pressure. There are ad- Pressure Regulator Module Specs Part Number Regulated Pressure Delivery Port Collar Color 12-18207-000 0 to 150 psi (1034 kPa) - Adjustable Violet 12-18207-030 30 psi (207 kPa) - Non-adjustable Green 12-18207-060 60 psi (413 kPa) - Non-adjustable Red 12-18207-080 80 psi (551 kPa) - Non-adjustable Black Table 14, Pressure Regulator Module Specs Business Class M2 Workshop Manual, Supplement 9, March 2006 300/11