Air Management Unit 42.19 Troubleshooting kPa), the delivery port (on relay module) should read pressure. pend on an optional second normally open pressure switch. Some versions have internal ports, some do not. See Table 15 for the variations of this module. Pressure switch "B" modules with P/Ns 12-18206- XXX have diodes wired in parallel with the internal pressure switches, all others do not. 7. Once the delivery port gauge reads systems pressure, close Valve "A" on the test apparatus. Next, open Valve "B" slightly so as to relieve the control port pressure very slowly while observing the pressure gauges.
When the control port pres- sure drops (pressure gauge on the test appara- tus) to approximately 8 to 14 psi (55 to 96 kPa), the pressure at the delivery port of the relay valve should exhaust and read zero pressure. Pressure Switch "B" Module General Information Pressure Switch "B" module comes in various con- figurations. All have at least one normally closed pressure switch. Differences between versions de- Pressure Switch "B" Module Part Number Switch 1 Switch 2 No. of Ports to SW 1 No. of Ports to SW 2 Module Cover Color (body always black) N.C. Closes @ psi (kPa) N.O. Opens @ psi (kPa) Int. Ext. Int. Ext. 12-18206-000 Yes 70±5 (483±34) 1 2 Natural (lt.
beige) 12-18206-001 Yes 70±5 (483±34) Yes 70±5 (483±34) 0 1 0 1 Black 12-18206-002 Yes 70±5 (483±34) 0 1 0 Black 12-18206-003 Yes 70±5 (483±34) Yes 70±5 (483±34) 1 1 0 1 Natural (lt. beige) 12-18206-004 Yes 70±5 (483±34) 0 1 Natural (lt. beige) 12-18206-005 Yes 70±5 (483±34) Yes 70±5 (483±34) 0 2 0 1 Black 12-18206-006 Yes 70±5 (483±34) No 70±5 (483±34) 0 2 0 1 Black 12-18206-007 Yes 70±5 (483±34) No 70±5 (483±34) 1 2 0 1 Natural (lt. beige) 12-18206-008 Yes 70±5 (483±34) Yes 3.5±1.5 (24±10) 0 1 0 1 Black 12-18206-009 Yes 70±5 (483±34) 1 1 0 Natural (lt. beige) 12-18206-010 Yes 70±5 (483±34) Yes 70±5 (483±34) 0 2 0 1 Black Business Class M2 Workshop Manual, Supplement 9, March 2006 300/14