Air Management Unit 42.19 Troubleshooting Pressure Switch "B" Module Part Number Switch 1 Switch 2 No. of Ports to SW 1 No. of Ports to SW 2 Module Cover Color (body always black) N.C. Closes @ psi (kPa) N.O. Opens @ psi (kPa) Int. Ext. Int. Ext. A12-19777-015 Yes 87±7 (600±48) 0 1 Black A12-19777-016 Yes 70±5 (483±34) 0 1 Black A12-19777-017/-117 No 3.5±1.5 (24±10) Yes 3.5±1.5 (24±10) 0 2 0 1 Black A12-19777-018 Yes 77±7 (531±48) Yes 70±5 (483±34) 1 2 0 1 Natural (lt.
beige) A12-19777-119 Yes 77±7 (531±48) Yes 3.5±1.5 (24±10) 0 2 0 1 Black Table 15, Pressure Switch "B" Module Pressure Switch "B" Tests be tested is normally open or normally closed (see Table 15 .) Then test the pressure switch using the appropriate tables that follow. For testing the pressure switches in pressure switch module first determine if the pressure switch to Business Class M2 Workshop Manual, Supplement 9, March 2006 300/16