Air Management Unit 42.19 Troubleshooting Testing Pressure Switch 1 Switch "B" Module (all with normally closed pressure switch 1) Test Conditions Test Point Good Result If Test Fails: Test if Switch Opens at Proper Pressure Chock tires. Key OFF, engine OFF. Resistance Check: Greater than 1 ohm. Faulty Pressure Switch "B". Replace it. Drain air tanks. Measured between pin A and B (switch side). NOTE: If the meter reads less than 1 ohm, then the pressure switch is not opening within the proper pressure range, and is therefore faulty. Pressure switch "B" 4-way connector disconnected. Disconnect one of the SW1 ports on the face of the module and connect a regulated air supply setup as in Fig.

1 to the SW1 port. Close valve "A" and valve "B" of the test apparatus. Back off the regulator screw so that the downstream pressure is zero. Connect shop air to the test apparatus. Open valve "A". Apply 5 psi (35 kPa) above the maximum opening pressure to the SW1 port by adjusting the pressure regulator. For example, if the opening pressure is 70–84 psi (483–579 kPa), then apply 89 psi (614 kPa) to the SW1 port. This should cause switch 1 to open. Test if Switch Closes at Proper Pressure Using the same apparatus as used in the previous test, close valve "A", then back the regulator off and bleed off all pressure to the SW1 port using valve "B".

Close valve "A" and valve "B" of the test apparatus. Back off the regulator screw so that the downstream pressure is zero. Connect shop air to the test apparatus. Open valve "A". Apply 5 psi (35 kPa) below the minimum opening pressure to the SW1 port by adjusting the pressure regulator. For example, if the opening pressure is 70–84 psi (483–579 kPa), then apply 65 psi (448 kPa) to the SW1 port. This should cause switch 1 to close. Resistance Check: Less than 1 ohm. Faulty Pressure Switch "B". Replace it. Measured between pin A and B (switch side).

Table 16, Testing Pressure Switch 1 -- Switch "B" Module (all with normally closed pressure switch 1) Business Class M2 Workshop Manual, Supplement 9, March 2006 300/17