Air Management Unit 42.19 Troubleshooting Testing Pressure Switch 2 Switch "B" Module (all with normally open pressure switch 2) Test Conditions Test Point Good Result If Test Fails: Test if Switch Opens at Proper Pressure Chock tires. Key OFF, engine OFF. Resistance Check: Greater than 1 ohm. NOTE: If the meter reads less than 1 ohm, then the pressure switch is not open within the proper pressure range, and is therefore faulty. Faulty Pessure Switch "B". Replace it. Drain air tanks. Measured between pin C and D (switch side). Pressure switch "B" 4-way connector disconnected. Do the following for all N.O. SW2 modules except for modules where the SW2 closing pressure is psi (15–35 kPa):
Disconnect one of the SW2 ports on the face of the module and connect a regulated air supply setup as in Fig.1 to the SW2 port. Close valve "A" and valve "B" of the test apparatus. Back off the regulator screw so that the downstream pressure is zero. Connect shop air to the test apparatus. Open valve "A". Apply 5 psi (35 kPa) below the minimum closing pressure to the SW2 port by adjusting the pressure regulator. For example, if the closing pressure is 65–75 psi (448–517 kPa), then apply 60 psi (414 kPa) to the SW2 port. This should cause switch 2 to be open. Business Class M2 Workshop Manual, Supplement 9, March 2006 300/20