Air Management Unit 42.19 Troubleshooting Testing Pressure Switch 2 Switch "B" Module (all with normally open pressure switch 2) Test Conditions Test Point Good Result If Test Fails: Test if Switch Closes at Proper Pressure Using the same apparatus as used in the previous test, close valve "A", then back the regulator off and bleed off all pressure to the SW2 port using valve "B". Resistance Check: Less than 1 ohm. Faulty Pressure Switch "B". Replace it. Measured between pin C and D (switch side). NOTE: If the meter reads greater than 1 ohms, then the pressure switch is not closing within the proper pressure range, and is therefore faulty. Close valve "A" and valve "B" of the test apparatus.

Back off the regulator screw so that the downstream pressure is zero. Connect shop air to the test apparatus. Open valve "A". Apply 5 psi (35 kPa) above the maximum closing pressure to the SW2 port by adjusting the pressure regulator. For example, if the closing pressure is 65–75 psi (448–517 kPa), then apply 80 psi (552 kPa) to the SW2 port. This should cause switch 2 to close. Table 19, Testing Pressure Switch 2 -- Switch "B" Module (all with normally open pressure switch 2) Business Class M2 Workshop Manual, Supplement 9, March 2006 300/21