Freightliner — Freightliner Business Class M2 Workshop Manual

Double Check Valve 42.20 Double Check Valve Removal and Installation Removal 2. Connect the air lines to the double check valve as marked. Push the air lines firmly into the quick-connect fittings. WARNING Wear safety goggles when draining the air sys- tem or disconnecting an air line because dirt or sludge particles could fly out at high speeds. Don’t direct the air streams at other people. Don’t disconnect pressurized hoses, since they may whip as air escapes. Failure to take all necessary precautions could result in personal injury. 1. Drain the air from the air reservoirs. 2. Disconnect the air lines from the double check valve. See Fig. 1 . 1 2 10/16/2001 f430278 1. Foot Brake Valve 2.

Double Check Valve Fig. 1, Brake Valve and Double Check Valve Plumbing 3. Unscrew the double check valve from the foot brake valve. Installation 1. Screw the double check valve into the foot brake valve. Tighten the valve firmly. Business Class M2 Workshop Manual, Supplement 0, January 2002 120/1