Air Dryer, Meritor WABCO System Saver 1200 42.28 Outlet Check Valve Assembly Replacement Replacement 9. Install a new washer and snap ring to secure the assembly in the valve cavity. WARNING 10. Connect the air line to the outlet port. Tighten the nut on the fitting finger-tight. Then, using two wrenches to prevent twisting the hose, further tighten the nut until there is firm resistance. Tighten the nut one-sixth turn more. Before starting the procedures below, read the information in Safety Precautions, 100. Failure to follow the safety precautions during service op- erations on the air brake system can cause per- sonal injury. 1. Drain the air system. 2.
Disconnect the air line from the outlet port. See Fig. 1 . 1 2 3 4 5 07/23/97 f421614 1. O-Ring 2. Valve Body 3. Spring 4. Washer 5. Snap Ring Fig. 1, Outlet Check Valve Assembly 3. Remove the snap ring, washer, valve body, and the O-ring. 4. Clean the cavity area with a commercial cleaning solvent. 5. Install a new O-ring on the valve body. 6. Using a multipurpose, high-temperature grease that resists water, steam, and alkali, lightly coat the surfaces of the new O-ring and the valve cavity. 7. Install the new valve body. Make sure that the long end of the body is inserted first into the valve cavity. 8. Install the new spring with its small end around the "Y" shaped fins on the valve body.
IMPORTANT: If the valve cavity is damaged, preventing a tight seal, replace the air dryer. Business Class M2 Workshop Manual, Supplement 6, September 2004 140/1