Air Dryer, Meritor WABCO System Saver 1200 42.28 Desiccant Cartridge Replacement Replacement the base, tighten the cartridge one complete turn more. Do not over-tighten. WARNING IMPORTANT: If the air dryer base is damaged, preventing a tight seal, replace the air dryer. Before starting the procedures below, read the information in Safety Precautions, 100. Failure to follow the safety precautions during service op- erations on the air brake system can cause per- sonal injury. 1. Drain the air system. 2. Using a strap wrench, turn the desiccant car- tridge counterclockwise and remove it. See Fig. 1 . 2 3 1 08/05/94 f421292 1. Seal 2. O-Ring 3. Air Dryer Base Fig.
1, Desicant Cartridge Replacement 3. Remove and discard the O-ring. 4. Clean the top surface of the dryer base with a commercial cleaning solvent. 5. Using a multipurpose, high-temperature grease that resists water, steam, and alkali, lightly coat the surfaces of the new O-ring and the dryer base. Install the O-ring. 6. Thread the desiccant cartridge onto the dryer base (turn clockwise). When the seal contacts Business Class M2 Workshop Manual, Supplement 6, September 2004 150/1