Air Dryer, Meritor WABCO System Saver 1200 42.28 Pressure-Controlled Check Valve Replacement Replacement 6. Install the new valve on the air tank. WARNING 7. Connect the air line to the air-line fitting on the valve. Tighten the air line securely. Before starting the procedures below, read the information in Safety Precautions, 100. Failure to follow the safety precautions during service op- erations on the air brake system can cause per- sonal injury. 1. Drain the air system. 2. Disconnect the air line from the fitting on the valve. See Fig. 1 . 5 3 4 2 1 04/05/95 f421297 1. Air Line 2. Nylon Tube Connector 3. Pressure-Controlled Check Valve 4. Hex Nipple Pipe Fitting 5. Air Tank 3.
Remove the air-line fitting firm the valve. Fig. 1, Check Valve Assembly Replacement 4. Remove the valve and the hex nipple fitting from the air tank. Then remove the nipple from the valve. NOTE: Apply liquid Loctite ® Hydraulic Sealant (brown), or an equivalent, to the threads of all fittings before installing them. Always apply seal- ant to the external threads so that any excess will be scraped off externally rather than inter- nally to the joint. 5. Install the pipe fittings on the new valve. Make sure that the arrow on the valve will be pointing towards the tank when installed. Business Class M2 Workshop Manual, Supplement 6, September 2004 200/1