Air Dryer, Meritor WABCO System Saver 1200 42.28 Operating Tests Operating Tests Pressure-Control Check Valve Operating Check WARNING 1. Start the engine and build the air pressure to cut- out pressure (about 125 psi [862 kPa]). Before starting the procedures below, read the information in Safety Precautions, 100. Failure to follow the safety precautions during service op- erations on the air brake system can cause per- sonal injury. 2. Stop the engine after the air compressor has un- loaded. 3. Drain the supply system air tank down to about 80 psi (552 kPa) or lower. Air Dryer Operating Check 4. Check the secondary air gauge. It should read 95 ±5 psi (655 ±34 kPa). 1. Drain the air system.
If the gauge reading is less that 90 psi (621 kPa), either the pressure-control check valve is installed backwards, it is damaged, or there are air leaks in the secondary air system. 2. Start the engine and build the air pressure to as close to cutout pressure as possible (about 125 psi [862 kPa]). 3. When the compressor reaches the unload cycle, the air dryer purges, beginning regeneration of the air dryer. If the secondary gauge reading does not change, or the reading does not fall below 100 psi (689 kPa): 4. During the purge cycle, which lasts about 10 to 15 seconds, the wet tank and secondary system tank with pressure-controlled check valve will drop about 10 psi (69 kPa).
Check the secondary system air gauge in the cab dash panel. There is no pressure-controlled check valve installed, or it is installed in the wrong tank. The pressure-controlled check valve is in- stalled into a one-way check valve, rather than in place of a one-way check valve. 5. If the secondary gauge needle does not show a pressure drop of about 10 psi (69 kPa), one of the following problems may exist. There is another check valve located be- tween the air dryer and the secondary air tank. A pressure-controlled check valve is not installed. The secondary air gauge is not plumbed to the secondary air system. The pressure-controlled check valve is in- stalled in the wrong air tank.
The pressure-controlled check valve is in- stalled on a one-way check valve, instead of in place of a one-way check valve. There is an extra check valve located somewhere between the air dryer and the secondary air tank (usually at the wet tank). The secondary air gauge is not plumbed to the secondary air system. 6. If system secondary air pressure drops 25 psi (172 kPa) or more during the purge cycle, and there are no other air-operated components in use, then there are air leaks or other system problems. Refer to Troubleshooting, 300 for other possible causes. Business Class M2 Workshop Manual, Supplement 6, September 2004 210/1