Freightliner — Freightliner Business Class M2 Workshop Manual

Air Dryer, Meritor WABCO System Saver 1200 42.28 Troubleshooting Troubleshooting Table Meritor WABCO System Saver 1200 Troubleshooting Meritor WABCO System Saver 1200 Troubleshooting Condition Possible Cause Solution Dryer leaks from purge valve during compressor-loaded cycle. The leak may cause excessive compressor cycling or prevent the system from building air pressure. Purge valve frozen open (cold weather operation). Check heater. Repair/replace if necessary. Make sure governor to dryer port 4 line is free of water/oil. Remove and inspect purge valve and clean water/oil from top of piston. Debris under purge valve seat, such as particles from fittings or air inlet line.

Disassemble and clean purge valve. Purge valve washer installed upside- down. Remove cartridge and clean dryer sump area. Ensure lip on aluminum washer faces DOWN, away from dryer. Wrong air-line connected to dryer port 4 (unloader port). Verify correct air-line installation and correct as needed. Purge valve snap-ring not fully seated in groove. Seat snap-ring fully into groove. Slight leak from purge valve. After several hours, the supply tank may be empty. Outlet check valve not seating or regeneration valve not shutting off regeneration airflow. Remove, inspect, and clean outlet check valve and regeneration valve diaphragms. Replace if worn or damaged.

Regeneration cycle too long (more than 30 seconds), accompanied by loss of pressure in the supply tank. Outlet check valve not seating. Inspect and replace outlet check valve as needed. Regeneration valve not shutting off regeneration airflow. Replace regeneration valve. Regeneration cycle too short (less than 10 seconds). High air system demands during compressor unloaded cycle. Increase air system capacity or reduce air demands. Pressure-controlled check valve not installed in system or not working properly. Check and replace pressur-econtrolled check valve as needed. One-way check valve installed in system reservoir instead of, or with, pressure-controlled check valve.

Remove one-way check valve. Make sure pressure-controlled check valve is installed correctly. Regeneration valve not working. Remove regeneration valve and clean oil from diaphragm. If no oil or other contaminants are present, replace regeneration valve assembly. Air governor not working properly. Inspect per manufacturer’s instructions and repair/replace as needed. Business Class M2 Workshop Manual, Supplement 6, September 2004 300/1