Freightliner — Freightliner Business Class M2 Workshop Manual

Air Dryer, Meritor WABCO System Saver 1200 42.28 Troubleshooting Meritor WABCO System Saver 1200 Troubleshooting Condition Possible Cause Solution No regeneration cycle. No airflow from purge valve after initial purge blast (dryer decompression). Air dryer not connected to supply tank or connections reversed at dryer. Verify proper dryer installation per system diagram. Regeneration valve not working. Replace regeneration valve. One-way check valve installed in supply tank. Remove one-way check valve. Alcohol evaporator installed between dryer and supply tank. Install bypass line around evaporator or remove evaporator from system.

Air dryer does not purge when compressor unloads (no blast of air from purge valve). Air line between governor and air dryer port 4 kinked or plugged. Repair air line. Purge valve stuck closed. Replace purge valve. Air governor not working properly. Inspect air governor. Repair/replace per manufacturer’s instructions. Cut-out pressure never achieved by air compressor. Check for air leaks in system and repair as needed. If no leaks in system, check compressor output. Repair/replace per manufacturer’s instructions. Air dryer purges too often, perhaps as frequently as every 15 seconds, accompanied by excessive cycling of the compressor. Leak in line between governor and dryer port 4.

Repair air line. Leak in line between supply tank and governor. Repair air line. Excessive air system leaks. Repair leaks. Excessive air system demands. Increase air system capacity or reduce air demand. Outlet check valve not seating. Inspect and replace outlet check valve as needed. Regeneration valve not shutting off properly. Replace regeneration valve. Air governor has less than 16 psi range. Replace air governor. Leaking air compressor unloader(s). Inspect compressor. Repair/replace per manufacturer’s instructions. Air flows out of purge valve entire time compressor is unloaded. Turbo cut-off valve not sealing. Replace turbo cut-off valve. NOTE:

With U Series air dryers the compressor unloads through the dryer, so a steady flow of air is normal. Rapid "spitting" of air from purge valve in small amounts. Frequency varies with engine speed. Holset E-type compressor used, but no Econ valve installed. Install Econ valve to provide make-up air to compressor. Compressor not completely unloading when cut-out pressure is reached. Inspect compressor. Repair/replace per manufacturer’s instructions. Business Class M2 Workshop Manual, Supplement 6, September 2004 300/2