Air Dryer, Meritor WABCO System Saver 1200 42.28 Troubleshooting Meritor WABCO System Saver 1200 Troubleshooting Condition Possible Cause Solution Air leak at turbo cut-off valve vent. Hole burned in piston. Temperature of air coming into dryer is too high—not enough cooling takes place before dryer inlet. Move dryer farther from compressor. Add additional compressor discharge line before air dryer. Add cooling coil or heat exchanger before air dryer. NOTE: Inlet air temperature must not exceed 175°F (80°C). Air leak at turbo cut-off valve vent. Lip seal installed upside-down on piston. Lip must face UP (towards dryer). Install lip seal correctly. Valve bore worn excessively.
Inspect valve bore for wear. If a new turbo cut-off valve does not seal in a clean, lubricated bore, replace the air dryer. Air dryer frozen (water collecting in base of dryer is freezing). No electrical power to heater connector. Check for a blown fuse. Repair heater circuit. NOTE: There must be power to the heater connector the entire time the vehicle’s ignition is ON. Low voltage to heater connector. Repair cause of low voltage, such as poor electrical ground, bad connections, corroded wire splices, etc. Heater assembly not working. Replace heater assembly. Wrong voltage air dryer used; i.e., 12- volt air dryer used in a 24-volt system. Replace with correct voltage air dryer.
No air pressure build-up in system. Air dryer not plumbed correctly (connections reversed). Ensure compressor discharge line is plumbed to air dryer port 1, and air dryer port 21 is connected to vehicle’s supply tank. Wrong air line connected to dryer port 4. Ensure dryer port 4 line is connected to the "UNL" port of the air governor. Air governor not working properly. Inspect governor per manufacturer’s instructions. Repair or replace as needed. Air system leaks, such as compressor discharge line, air dryer, reservoirs, brake or suspension valves, etc. Locate leak(s) and repair. Air dryer leaks from purge valve. Refer to purge valve conditions listed in this chart.
Water in tanks; often following aftermarket installation or when dryer is a replacement for a competitive brand. Pressure-controlled check valve not installed in correct tank or not installed at all. Install pressure-controlled check valve in secondary tank. Pressure-controlled check valve properly installed, but one-way check valve not removed. Remove one-way check valve so that only the pressure-controlled check valve is installed between the secondary tank and supply tank. Business Class M2 Workshop Manual, Supplement 6, September 2004 300/3