Freightliner — Freightliner Business Class M2 Workshop Manual

Parking Brake Hand Valve, Bendix PP–DC 42.29 Parking Brake Hand Valve Tests IMPORTANT: To do the following tests, ensure that two separate 120 psi (827 kPa) vehicle air sources are connected to the PP–DC supply ports. See Fig. 1. Tee an accurate test gauge into the supply lines, and provide for a means to control supply line pressure. Connect a small volume air source with a gauge to the delivery port. 3. With the valve knob pulled out, supply either supply port with 120 psi (827 kPa) of pressure. Push the valve knob in. Air pressure should rise in the delivery line and equal supply line pres- sure. Pull the valve knob out. Delivery pressure should exhaust to zero. 4.

Build air pressure to each supply source to 120 psi (827 kPa). Decrease supply pressure at the secondary service reservoir supply port at a rate of 10 psi (69 kPa) per second. Operating Test 1. Chock the tires. 2. Start the engine and build up the air pressure to the normal operating level. 4 3 5 2 6 7 1 07/18/95 f421347 1. Primary Service Reservoir 2. Supply Port 3. Secondary Service Reservoir 4. Valve Knob 5. Delivery Port 6. Brake Chamber 7. Exhaust Port Fig. 1, Parking Brake Hand Valve (sectional view) Business Class M2 Workshop Manual, Supplement 6, September 2004 110/1