Freightliner — Freightliner Business Class M2 Workshop Manual

Parking Brake Hand Valve, Bendix PP–DC 42.29 Parking Brake Hand Valve Tests Primary supply pressure and delivery pressure should not drop below 100 psi (689 kPa). Repeat this step for decreasing primary service reservoir pressure. 5. Build air pressure to each supply source to 120 psi (827 kPa). Then, decrease both supply pres- sures to below 20 to 30 psi (138 to 207 kPa). The valve knob should automatically pop out when the pressure is within that range. NOTE: Normally, the valve will pop out. In the event that it does not pop out, make sure that the brakes are applying as they are supposed to. If the brakes are working correctly, the valve is still functioning properly. 6.

If the valve does not work as described, repair the valve or replace it following instructions under Subject 130. Leak Testing 1. Chock the tires. 2. Supply the valve with 120 psi (827 kPa) from the primary reservoir supply port. 3. With the valve knob pulled out, coat the exhaust port and the plunger stem with a soapy solution. Leakage at either fitting should not exceed a 1-inch (2.5 cm) bubble every five seconds. There should be no leakage from the secondary reser- voir supply port. 4. Supply the valve with 120 psi (827 kPa) from the secondary reservoir supply port. There should be no leakage from the primary reservoir supply port. 5.

With the valve knob pushed in, coat the exhaust port and the plunger stem with a soapy solution. Leakage at the fittings should not exceed a 1-inch (2.5 cm) bubble every three seconds. If it does, replace or repair the valve, following in- structions in Subject 130. Business Class M2 Workshop Manual, Supplement 6, September 2004 110/2