Modulating Valve, Bendix SR-7 42.31 General Information CAUTION Do not attempt to disassemble the SR-7 valve. The valve contains high spring forces that could result in personal injury if disassembly is at- tempted. B 2 Operation A The operation guidelines shown in this manual repre- sent the relay valve based SR-7. A quick-release- based valve functions similarly to the relay-valve- based version with the exception that all air delivered to the spring brakes passes through the park control port through the in-line single check valve. The SR-7 quick release style can be easily identified by the pipe plug in the supply port of the valve. See Fig. 1 .

For vehicle-specific plumbing diagrams, go to EZWir- ing . Charging the Spring Brake Actuators Below 107 PSI (737 kPa) 3 C f422421 10/11/2005 1 A. Secondary reservoir constant pressure B. Control line pressure C. Delivery to spring brakes 1. Inlet/Exhaust Valve Open 2. Balance Port 3. Control Port With the air brake system charged and the parking brakes released (by pushing in the dash valve but- ton), air enters the park control port. This opens the SR-7 valve, to supply air pressure to the spring brake chambers. As illustrated, air pressure in the chambers is below 107 psi (737 kPa) (nominal). See Fig. 3 . Charging the Spring Brake Actuators Above 107 psi (737 kPa) Fig.

3, Charging the Spring Brake Actuators Below 107 PSI (737 kPa) Parking Actuating the park brakes (by pulling out the dash valve button) exhausts spring brake air pressure through the SR-7 valve exhaust port. See Fig. 6 . Service Application with Loss of Air in Primary Circuit Once the SR-7 valve delivery pressure reaches 107 psi (nominal), the inlet and exhaust are closed (valve lap position). This maintains the spring brake hold-off pressure at 107 psi (nominal). See Fig. 4 .

Normal Service Application With the parking brakes released (dash valve button in) and the absence of air in the primary circuit deliv- ery, a service brake application from the secondary circuit causes the pressure in the spring brakes to be exhausted proportionally to this application. This is known as spring brake modulation. A 30 psi (207 kPa) service brake application will exhaust the spring brake pressure to approximately 60 psi (414 kPa). See Fig. 7 . During a service brake application, the valve remains in the lap position. The SR-7 valve monitors the presence of air pressure in both primary and second- ary delivery circuits. See Fig. 5 .

Business Class M2 Workshop Manual, Supplement 9, March 2006 050/3