Modulating Valve, Bendix SR-7 42.31 General Information B B 2 3 A A C D C E 1 1 f422422 10/11/2005 A. Secondary reservoir constant pressure B. Control line pressure C. Delivery to spring brakes 1. Inlet/Exhaust Valve Seated 2. Balance Port 3. Control Port f422423 10/11/2005 A. Secondary reservoir constant pressure B. Control line pressure C. Balance port—primary circuit pressure D. Control port—secondary circuit pressure E. Delivery to spring brakes 1. Inlet/Exhaust Valve Seated Fig. 4, Charging the Spring Brake Actuators Above 107 PSI hausted from the spring brake chambers and the ve- hicle remains parked using the spring brake actua- tors. See Fig. 9 . Fig.
5, Normal Service Application Service Application with Loss of Air in Secondary Circuit With the parking brakes released (dash valve button in) and the absence of air in the secondary circuit reservoir, the external single check valve in the sup- ply port seals to prevent air leakage to atmosphere from the SR-7 valve. The dash valve delivery air flows through the inline single check valve and be- comes SR-7 valve supply air. This air is delivered to maintain at least 107 psi (737 kPa) (nominal) in the spring brake chambers. See Fig. 8 . Anti-Compounding The SR-7 valve provides anti-compounding of the service and spring brake forces.
When the park brakes are actuated (by pulling out the dash valve button), a service brake application will cause the SR-7 valve to deliver air pressure to the spring brake chambers. Thus the vehicle is held stationary using a service brake application. When the service brake application is released, the delivery pressure is ex- Business Class M2 Workshop Manual, Supplement 9, March 2006 050/4