Freightliner — Freightliner Business Class M2 Workshop Manual

AD-IS Air Dryer, Bendix 42.33 General Information General Information The air dryer will remain in the charge cycle until the air brake system pressure builds to the governor cut- out setting of approximately 130 psi (896 kPa). The function of the Integrated Solution Air Dryer (AD- IS ® ) and reservoir system is to provide vehicles with an integrated air dryer, purge reservoir, governor, and a number of the charging valve components in a module. See Fig. 1 . Purge Cycle Figure 3 shows the purge cycle. The AD-IS ® air dryer and reservoir system collects and removes air system contaminants in solid, liquid, and vapor form before they enter the brake system.

It provides clean, dry air to the components of the brake system, which increases the life of the system. Charge Cycle When air brake system pressure reaches the cutout setting of the governor, the governor unloads the compressor and the purge cycle begins. When the governor unloads the compressor, it pressurizes the compressor unloader mechanism and the dryer con- trol port. The purge piston moves in response to air pressure, causing the purge valve to open and the turbo cutoff valve to close. When the purge valve opens, water and contaminants are expelled. Air flowing through the desiccant cartridge changes di- rection and begins to flow toward the open purge valve.

Oil and solid contaminants collected in the oil separator are removed by air flowing from the purge reservoir, through the desiccant drying bed, and out through the open purge valve. When the compressor is loaded, compressed air, oil, oil vapor, water, and water vapor flow through the compressor discharge line to the inlet port of the air dryer body. Figure 2 shows the charge cycle. As air travels through the air dryer assembly, its tem- perature falls, causing some of the contaminants to condense and drop to the bottom of the air dryer as- sembly, ready to be expelled at the next purge cycle.

The purge cycle lasts only a few seconds and is de- tected by an audible burst of air at the air dryer exhaust. The air then flows into the desiccant cartridge. Once in the desiccant cartridge, air flows through an oil separator which removes oil and solid contaminants. The reactivation of the desiccant drying bed begins as dry air flows from the purge reservoir, through the purge orifice, and into the desiccant bed. Pressurized air from the purge reservoir expands after passing through the purge orifice; its pressure is lowered and its volume is increased. The flow of dry air through the drying bed reactivates the desiccant material by removing the water vapor adhering to it.

Approxi- mately 30 seconds is required for the entire purge reservoir of a standard air dryer to flow through the desiccant dryer bed. Air then flows into the desiccant drying bed. Air flow- ing through the desiccant becomes progressively dryer as water vapor adheres to the desiccant mate- rial. Dry air exits the bottom of the desiccant cartridge and flows through the center of the base assembly. The air then flows to the delivery check valve, to the safety valve and also through an orifice plug into the purge reservoir. Air traveling through the delivery check valve flows to the governor and the four pres- sure protection valves.

The delivery check valve assembly prevents air pres- sure in the brake system from returning to the air dryer during the purge cycle. After the purge cycle is complete, the air dryer is ready for the next charge cycle to begin. Turbo Cutoff Feature As pressure builds during the initial charge, the purge reservoir fills. When the air pressure reaches 106 psi (731 kPa), the four pressure protection valves open and air is supplied to the primary reser- voir, secondary reservoir, and accessories. If the pressure protection valves are preset to different val- ues, the valves open in order of the lowest to the highest setting when charging a flat system.

The primary function of the turbo cutoff valve is to prevent loss of turbocharger air pressure through the air dryer when the dryer is in the unloaded mode. During the purge cycle, the downward travel of the purge piston is stopped when the turbo cutoff valve contacts its mating metal seat in the purge valve Business Class M2 Workshop Manual, Supplement 20, September 2011 050/1