AD-IS Air Dryer, Bendix 42.33 Troubleshooting Problem—Air Dryer Does Not Purge or Exhaust Air Possible Cause Remedy The governor is inoperative. Check the governor for proper cut-in and cut-out pressures, and excessive leakage in both positions. Repair or replace as needed. The purge valve control piston quad-ring is leaking. Repair or replace the purge valve assembly.
Problem—Desiccant Is Being Expelled from the Air Dryer Purge Valve Exhaust (may look like whitish liquid, paste, or small beads); or, Unsatisfactory Desiccant Life Problem—Desiccant Is Being Expelled from the Air Dryer Purge Valve Exhaust (may look like whitish liquid, paste, or small beads) or Unsatisfactory Desiccant Life Possible Cause Remedy This problem usually occurs with one or more of the previous problems. Refer to the appropriate corrections listed previously. The air dryer is not securely mounted; there is excessive vibration. Vibration should be held to a minimum. Tighten the mounting fasteners.
Cloth-covered perforated plate in the air dryer desiccant cartridge is damaged, or the cartridge was rebuilt incorrectly. Replace the plate or cartridge as needed. High operating temperatures may cause deterioration of filter cloth. Check the installation. Compressor is passing excessive oil. Check for proper compressor installation; if symptoms persist, replace the compressor. Heater and thermostat, wiring, or a fuse is at fault, and isn’t allowing the air dryer to purge during cold weather. Test the heater and thermostat. Refer to Subject 170 for instructions. Desiccant cartridge is not attached properly to the end cover. Check the torque and tighten if necessary.
Refer to Subject 120 for instructions. Problem—Pinging Noise Is Excessive During Compressor Loaded Cycle Problem—Pinging Noise Is Excessive During Compressor Loaded Cycle Possible Cause Remedy Pinging noise is due to a single cylinder compressor with high pulse cycles. A slight pinging sound may be heard during system build-up when a single cylinder compressor is used. If this sound is deemed objectionable, it can be reduced substantially by increasing the discharge line volume. This is done by adding a 90 in 3 (1475 cm 3 ) reservoir between the compressor and the air dryer.
Problem—Air Dryer Purge Piston Cycles Rapidly in the Unloaded Mode Problem—Air Dryer Purge Piston Cycles Rapidly in the Unloaded Mode Possible Cause Remedy Compressor does not "unload." Check the air hose from the governor to the compressor for a missing, kinked, or restricted line. Repair or replace the air hose as needed. Repair or replace the compressor unloader. Business Class M2 Workshop Manual, Supplement 20, September 2011 300/3