AD-IS Air Dryer, Bendix 42.33 Troubleshooting Problem—Safety Valve on Air Dryer Is Popping Off or Exhausting Air Possible Cause Remedy Problem—Safety Valve on Air Dryer Is Popping Off or Exhausting Air The check valve is defective. Test to determine if air is passing through the check valve. Repair or replace as needed. Safety valve setting is lower than the maximum system pressure. Reduce the system pressure, or install a safety valve with a higher pressure setting. System pressure is too high. Using an accurate gauge, test the system. Replace the governor if needed. There are excessive pressure pulsations from the compressor. Increase the volume in the discharge line.

This can be done by adding a 90 in 3 (1475 cm 3) [or larger] reservoir between the compressor and the air dryer and reservoir system. Problem—Constant Exhaust of Air at the Air Dryer Purge Valve Exhaust; Unable to Build System Pressure Problem—Constant Exhaust of Air at the Air Dryer Purge Valve Exhaust; Unable to Build System Pressure Air dryer purge valve is leaking excessively. With the compressor loaded, apply a soap solution on the purge valve exhaust to test for excessive leakage. Repair the purge valve as needed. Possible Cause Remedy The governor is inoperative. Check the governor for proper cut-in and cut-out pressures, and excessive leakage in both positions.

Repair or replace as needed. Purge valve is frozen open due to an inoperative heater or thermostat, bad wiring, or a blown fuse. Test the heater and thermostat, following instructions in this manual. The check valve is inoperative. Refer to "Problem—Air Dryer Is Constantly Cycling or Purging." The turbo cut-off valve is leaking. Repair or replace the purge valve assembly. The purge valve control piston quad-ring is leaking. Repair or replace the purge valve assembly. Discharge line is kinked or blocked. See if air passes through the discharge line. Check for kinks, bends, or excessive carbon deposits. There are excessive bends in the discharge line. Water is collecting and freezing.

Discharge line should be constantly sloping from the compressor to the air dryer with as few bends as possible. Pressure protection valves in the air dryer will not open. Replace the air dryer; pressure protection valves are not serviceable. Problem—Air Dryer Does Not Purge or Exhaust Air Problem—Air Dryer Does Not Purge or Exhaust Air Possible Cause Remedy The air dryer purge valve is not working. Make certain that air reaches the purge valve control port by installing a T-fitting with a pressure gauge into the governor unloader port. Repair the purge valve if needed. Purge valve is frozen open due to an inoperative heater or thermostat, bad wiring, or a blown fuse.

Test the heater and thermostat. Refer to Subject 170 for instructions. Business Class M2 Workshop Manual, Supplement 20, September 2011 300/2