AD-IS Air Dryer, Bendix 42.33 Troubleshooting Problem—Air Dryer Is Constantly Cycling or Purging Problem—Air Dryer Is Constantly Cycling or Purging Excessive system leakage. Test for excessive leakage. Eliminate leaks, as needed. Allowable leakage is as follows: Possible Cause Remedy Single Vehicle—1 psi/min (7 kPa/min) per service reservoir Tractor/Trailer—3 psi/min (21 kPa/min) per service reservoir There is excessive leakage in the fittings, hoses, and tubing connected to the com- pressor, air dryer, and wet tank. Using a soap solution, test for leakage at the fittings, drain valve, and safety valve in the wet tank. Repair or replace as needed.

The check valve assembly in the air dryer end cover is not working. Remove the check valve assembly from the end cover. Apply compressed air to the delivery side of the valve. Apply a soap solution at the opposite end, and check for leakage. Permissible leakage is a 1-inch (2.5-cm) bubble in 5 seconds. If there is excessive leakage, replace the check valve assembly. Governor is inoperative. Test the governor for proper cut-in or cut-out pressures and excessive leakage in both positions. Compressor unloader mechanism is leak- ing excessively. Remove the air strainer or fitting from the compressor inlet cavity. With the compressor unloaded, check for unloader piston leakage.

Slight leakage is allowed. Problem—Water in the Vehicle Reservoirs Possible Cause Remedy Problem—Water in the Vehicle Reservoirs Desiccant cartridge assembly contains excessive contaminants. Replace the desiccant cartridge. Discharge line is of improper length or material. Discharge line must consist of at least 6 ft (1.8 m) of wire braid Teflon hose, copper tubing, or a combination of both between the discharge port of the compressor and the air dryer supply port. Discharge line lengths and inside diameter requirements are dependent on the vehicle application. Contact your local Bendix representative for further information.

Air system was charged from an outside air source that did not pass through an air dryer. If the system must have an outside air fill provision, the outside air should pass through an air dryer. This practice should be minimized. The air dryer is not purging. Refer to "Problem—Air Dryer Does Not Purge or Exhaust Air." Purge (air exhaust) is insufficient due to excessive system leakage. Refer to "Problem—Air Dryer Is Constantly Cycling or Purging." Air bypasses the desiccant cartridge assembly. Replace the desiccant cartridge/end cover O-ring. Make sure the desiccant cartridge assembly is properly installed. Purge (air exhaust) time is significantly less than the minimum allowable.

Replace the desiccant cartridge/end cover O-ring. Make sure the desiccant cartridge assembly is properly installed. Replace the desiccant cartridge assembly. Excessive air usage—air dryer not compatible with vehicle air system. Install an accessory bypass system. Consult your Bendix representative for additional information. Business Class M2 Workshop Manual, Supplement 20, September 2011 300/1