Air Dryer, Meritor WABCO System Saver 1200 Plus 42.34 Troubleshooting Problem—Air Dryer Purges Too Often and Is Accompanied by Excessive Cycling of the Compressor Problem—Air Dryer Purges Too Often and Is Accompanied by Excessive Cycling of the Compressor There is a leak in the line between the unloader port of the air compressor and dryer port 4. Possible Cause Remedy Repair the air line. There is a leak in the line between the supply tank and the delivery/outlet port. Repair the air line. Excessive air system leaks. Repair all leaks. Excessive air system demands. Increase the air system capacity or reduce air demand. The outlet check valve does not seal.
Inspect and replace the outlet check valve as needed. There is a leak at the air governor gasket. Replace the gasket. The air governor has less than 16 psi (110 kPa) range. Replace the air governor. The air compressor’s unloader(s) is leaking. Inspect the air compressor and repair or replace it according to the manufacturer’s instructions. Problem—The Air Dryer Does not Purge When the Compressor Unloads (No Blast of Air from the Purge Valve) Problem—The Air Dryer Does not Purge When the Compressor Unloads (No Blast of Air from the Purge Valve) Possible Cause Remedy The air line between the unloader port of the air compressor and air dryer port 4 is kinked or plugged. Repair the air line.
The purge valve is stuck closed. Replace the purge valve. The air governor is not working properly. Inspect the air governor and repair or replace it according to the manufacturer’s instructions. Cut-out pressure is never achieved by the air compressor. Check for air leaks in the system and repair as needed. If no leaks are found, check the compressor output. Repair or replace the compressor according to the manufacturer’s instructions.
Problem—There Is Rapid "Spitting" of Air from the Purge Valve in Small Amounts; Frequency Varies With Engine Speed Problem—There Is Rapid "Spitting" of Air from the Purge Valve in Small Amounts; Frequency Varies With Engine Speed Possible Cause Remedy A Holset E-type compressor is being used, but a non-1200E air dryer is installed. Replace the air dryer with an SS1200E air dryer. The compressor does not completely unload when cut-out pressure is reached. Inspect the compressor and repair or replace it according to the manufacturer’s instructions. This is normal for air dryers that are not equipped with an optional turbocharger cutoff valve. Not applicable.
Business Class M2 Workshop Manual, Supplement 21, March 2012 300/1