Air Dryer, Meritor WABCO System Saver 1200 Plus 42.34 Troubleshooting Problem—Air Leaks at the Turbo Cutoff Valve Vent; There Is a Hole Burned in the Piston Possible Cause Remedy Problem—Air Leaks at the Turbo Cutoff Valve Vent; There Is a Hole Burned in the Piston The temperature of the air coming into the dryer is too high, and there is not enough cooling taking place before the air gets to the air dryer inlet. Move the dryer farther from the compressor. Add additional compressor discharge line before the air dryer. Add a cooling coil or heat exchanger before the air dryer. NOTE: The inlet air temperature must not exceed 175°F (79°C). The valve bore is worn excessively.

Inspect the valve bore for wear. If a new turbo cut-off valve does not seal in a clean, lubricated bore, replace the air dryer. The piston is broken. Replace the turbocharger cutoff valve. See Subject 120 . Problem—The Air Dryer Is Frozen (Water Collected in the Base of the Air Dryer Freezes) Problem—The Air Dryer Is Frozen (Water Collected in the Base of the Air Dryer Freezes) Possible Cause Remedy There is no power to the heater connector. Check for a blown fuse. Repair the heater circuit. NOTE: There must be power to the heater connector the entire time the vehicle’s ignition is activated. Low voltage to the heater connector.

Repair the cause of low voltage—poor electrical ground, bad connections, corroded wire splices, etc. The heater assembly is not working. Replace the heater assembly. An incorrect voltage air dryer is being used (for example a 12V air dryer in a 24V system). Replace with the correct voltage air dryer. Problem—Air Pressure Will Not Build-Up in the System Problem—Air Pressure Will Not Build-Up in the System Possible Cause Remedy The air dryer is not plumbed correctly. Make certain the compressor discharge line is plumbed to air dryer port 1, and air dryer port 21 is connected to the vehicle’s supply tank. The wrong air line is connected to air dryer port 4.

Verify that the air dryer port 4 line is connected to the "UNL" port of the unloader port of the air compressor. The air governor is not working properly. Inspect the air governor and repair or replace it according to the manufacturer’s instructions. Air system components, such as the compressor discharge line, air dryer reservoirs, brake valves, or suspension valves leak. Locate the leak(s) and repair as needed. The air dryer leaks at the purge valve.

See Air dryer purges too often and is accompanied by excessive cycling of the compressor and The air dryer leaks from the purge valve during a compressor loaded cycle (the leak may cause excessive compressor cycling or prevent the system from building air pressure). Business Class M2 Workshop Manual, Supplement 21, March 2012 300/2