Freightliner — Freightliner Business Class M2 Workshop Manual

Air Dryer, Meritor WABCO System Saver 1200 Plus 42.34 Troubleshooting Problem—Water, Oil, or Sludge Is in the Air System Tanks Problem—Water, Oil, or Sludge Is in the Air System Tanks Desiccant is contaminated with oil. Replace desiccant. Inspect the compressor according to the manufacturer’s instructions. Possible Cause Remedy Problem—Water Is in the Air System Tanks Problem—Water Is in the Air System Tanks Possible Cause Remedy The air dryer is not suitable for the vehicle. Review the vehicle guidelines. Call the Meritor Customer Support Center for assistance at 1-800-535-5560.

Problem—The air dryer leaks from the purge valve during a compressor loaded cycle (the leak may cause excessive compressor cycling or prevent the system from building air pressure) Problem—The air dryer leaks from the purge valve during a compressor loaded cycle. The leak may cause excessive compressor cycling or prevent the system from building air pressure. Possible Cause Remedy The purge valve is frozen open. Check the heater, and repair or replace it if necessary. Make sure the air line between the unloader port of the air compressor and dryer port 4 is free of water and oil. Remove and inspect the purge valve, and clean any water or oil from the top of the piston.

Debris is under the purge valve seat. Remove the purge valve and clean it. See Subject 130 for instructions to remove the purge valve. Remove the desiccant cartridge and clean the dryer sump area. See Subject 150 for instructions. The purge valve washer is installed upside down. Make certain the lip on the washer faces down, away from the air dryer. The wrong air line is connected to air dryer port 4. Verify that the dryer port 4 line is connected to the "UNL" port of the air compressor. The purge valve snap ring is not fully seated in the groove. Seat the snap ring fully into the groove.

Problem—The regeneration cycle is too long (more than 30 seconds), accompanied by loss of pressure in the supply tank Problem—The regeneration cycle is too long (more than 30 seconds), accompanied by loss of pressure in the supply tank Possible Cause Remedy The outlet check valve is not seating. Inspect the outlet check valve. Replace the valve if needed. Problem—The regeneration cycle is too short (less than 20 seconds) Problem—The regeneration cycle is too short (less than 20 seconds) There are high air system demands during a compressor unloaded cycle. Increase the air system capacity or reduce air demands.

Possible Cause Remedy Business Class M2 Workshop Manual, Supplement 21, March 2012 300/3