Batteries 54.03 Battery Testing Test Message—INTERNAL ERROR, SERVICE REQUIRED Possible Cause Remedy Test Message—INTERNAL ERROR, SERVICE REQUIRED The analyzer has detected a hardware or software problem. See the Midtronics Micro740 Instruction Manual. Test Message—REVERSE CONNECTION Possible Cause Remedy Test Message—REVERSE CONNECTION The clamps are connected in reverse polarity. IE: Red to negative(-) and black to positive ( + ). Disconnect the clamps and reclamp to proper polarity. Test Message—UNSTABLE BATTERY Test Message—UNSTABLE BATTERY Batteries that are very weak or that have just been charged may have sufficient electrical activity to alter test results.
The analyzer will automatically retest when the battery has stabilized. Fully charged batteries should stabilize quickly. Possible Cause Remedy Charge weak batteries and then retest. See Subject 150 . Test Message—CHECK CONNECTION Test Message—CHECK CONNECTION Possible Cause Remedy Poor connection. Both sides of the clamps must be firmly connected before testing. Clean the battery terminals using a wire brush and a mixture of baking soda and water. Inspect and clean the clamps. Liberally apply baking soda and water with a clean cloth and thoroughly rub the jaw and spring. Use a soft wire brush to remove corrosion buildup. Rinse with water and let dry.
Load Test When charging batteries, always wear eye protec- tion. During charging, batteries give off explosive hydrogen gas. Exploding gas can cause blind- ness or other bodily injury. NOTE: This test must not be used by U.S. and Canadian dealers for battery warranty claims. 2. Test each battery separately, either installed or removed. Disconnect the battery ground cable first. 1. Before beginning the load test, make sure the battery to be tested is fully charged. See Sub- ject 150 for conventional battery and gel cell charging instructions. 3. Connect the tester leads to the battery terminals following the tester manufacturer’s instructions.
Batteries with sealed terminals require adaptors to provide a place for attaching the tester’s leads. See Fig. 3 . WARNING Before charging a battery, read the instructions in Subject 120 . Failure to follow the safety pre- cautions could result in personal injury. 4. Check the rated CCA of the battery. Apply a load equal to one-half the rated CCA across the termi- nals for 15 seconds to remove the surface Business Class M2 Workshop Manual, Supplement 10, September 2006 140/4