Batteries 54.03 Battery Testing 1 1 06/20/2003 f540030d 1. Terminal Adaptor Fig. 3, Sealed Battery charge from the battery. Remove the load and wait 15 seconds for the battery to recover. For example, for a battery rated at 620 CCA, apply a load of 310 amperes across the termi- nals. 5. Estimate the battery temperature by touch and by the ambient temperature the battery was ex- posed to before this test, then find the voltage in the applicable table, Specifications 400 that must be maintained while the battery supplies a specified electrical load. For example, at 70°F (21°C) the battery must supply 9.6V minimum. 6. Apply the specified test load to the battery for 15 seconds.
The test load (amperes) is equal to one-half of the cold-cranking amperes of the 0°F (–18°C) rating of the battery. 7. Read the terminal voltage at the end of 15 sec- onds with the load still connected. Do not keep the load attached for a longer period of time be- fore reading the voltage, as this would alter the test results. 8. Remove the load after 15 seconds and note the tester reading. If the voltage drops below the minimum listed in the table replace the battery. If the voltage is the same or greater than the minimum listed in the table the battery is capable of further service. Business Class M2 Workshop Manual, Supplement 10, September 2006 140/5