Batteries 54.03 Specifications Minimum Permissible Voltages Ambient Temperature °F (°C) Minimum Voltage (after 15 seconds at 300 amps) 12-Volt 70 (21) and Above 9.6 60 (16) 9.5 50 (10) 9.4 40 (4) 9.3 30 (–1) 9.1 10 (–12) 8.7 20 (–7) 8.9 0 (–18) 8.5 Table 1, Minimum Permissible Voltage at Various Ambient Temperatures Charging Rates for Starting Batteries Rated Battery Capacity (reserve minutes) Slow Charge * Fast Charge Hours @ Amperes Hours @ Amperes 180 30 5 7-1/2 20 15 10 5 30 2-1/2 45 * Slow charging is recommended for completely charging the batteries.
An emergency boost charge, which consists of a high charging rate, can be obtained by reducing the fast- charge time to half, while maintaining the same recommended ampere charge may be used to crank an engine. Table 2, Charging Rates Approved Electrical Lubricants Manufacturer Lubricant or Part Number Shell Oil Co. No. 71032; No. 71306 Texaco, Inc. No. 955 Quaker State No. NYK–77 Table 3, Approved Electrical Lubricants Standard Battery Specifications Reserve Capacity Cold Cranking Amps (CCA) 180 minutes 750 Table 4, Standard Battery Specifications Business Class M2 Workshop Manual, Supplement 10, September 2006 400/1