Datalinks 54.10 Troubleshooting the J1939 Datalink Test 4: Pinpointing Short Circuits on the J1939 Datalink 1. Disconnect the 76-pin cab-to-engine bulkhead connector that contains J1939 wiring. 2. Turn the ignition on. The following test procedure pinpoints shorts to power and shorts to ground on the J1939 datalink. The tests will indicate which side of the cab/engine interface the problem exists. It will indicate whether the problem is in the wiring outside or inside the cab. 3. Touch the positive (+) lead to pin B (+12 VDC) and the negative lead to pin C (J1939+) of the diagnostic connector. 4. See Table 8 for test results and possible causes. Test 4.2:
Pinpoint J1939– for Short to Power or Ground NOTE: All tests are performed using a DMM set to read voltage. Before proceeding, verify that battery voltage (approximately +12 VDC) is available at pin B of the diagnostic connector. With the ignition on, use a DMM to test for voltage at pin B by plac- ing the positive (+) lead on pin B and the nega- tive lead on a good chassis ground. Only perform this test procedure if directed here in Test 3.2 . 1. Disconnect the 76-pin cab-to-engine bulkhead connector that contains J1939 wiring. 2. Turn the ignition on. 3. Touch the positive (+) lead to pin B (+12 VDC) and the negative lead to pin D (J1939–) of the diagnostic connector. Test 4.1:
Pinpoint J1939+ for Short to Power or Ground 4. See Table 9 for test results and possible causes. Only perform this test procedure if directed here in Test 3.1 . Result Possible Cause Test 2.3: Install a Test ECU to Confirm the Problem All ECUs respond. The ECU was faulty and the test ECU confirmed this. Replace the ECU. The ECU still does not respond. The problem has not been confirmed. Carefully repeat all the diagnostics. If the ECU still does not respond, contact Freightliner for assistance. Table 5, Test 2.3: Install a Test ECU to Confirm the Problem Result Possible Cause Test 3.1: Test J1939+ for Shorts to Power and Ground 0 VDC J1939+ is shorted to power. Go to Test 4.1 .
12 VDC (battery voltage) J1939+ is shorted to ground. Go to Test 4.1 . Any other reading J1939+ is neither shorted to power or ground. Go to Test 3.2 . Table 6, Test 3.1: Test J1939+ for Shorts to Power and Ground Test 3.2: Test J1939– for Shorts to Power and Ground Result Possible Cause 0 VDC J1939– is shorted to power. Go to Test 4.2 . 12 VDC (battery voltage) J1939– is shorted to ground. Go to Test 4.2 . Business Class M2 Workshop Manual, Supplement 10, September 2006 310/4