Datalinks 54.10 Troubleshooting the J1939 Datalink Test 3.2: Test J1939– for Shorts to Power and Ground Result Possible Cause Any other reading J1939– is neither shorted to power or ground. There may be a problem with the PC-to- vehicle communications adaptor or cables. The datalink itself appears to be okay. Table 7, Test 3.2: Test J1939– for Shorts to Power and Ground Test 4.1: Pinpoint J1939+ for Short to Power or Ground Result Possible Cause 0 VDC J1939+ is shorted to power inside the cab. Locate and repair the short. 12 VDC (battery voltage) J1939+ is shorted to ground inside the cab. Locate and repair the short. Any other reading J1939+ is shorted to power or ground outside the cab.
Locate and repair the short. Table 8, Test 4.1: Pinpoint J1939+ for Short to Power or Ground Test 4.2: Pinpoint J1939– for Short to Power or Ground Result Possible Cause 0 VDC J1939– is shorted to power inside the cab. Locate and repair the short. 12 VDC (battery voltage) J1939– is shorted to ground inside the cab. Locate and repair the short. Any other reading J1939– is shorted to power or ground outside the cab. Locate and repair the short. Table 9, Test 4.2: Pinpoint J1939– for Short to Power or Ground Business Class M2 Workshop Manual, Supplement 10, September 2006 310/5