Smart Switches 54.14 Troubleshooting what smart switches the Bulkhead Module actu- ally recognizes as being on the vehicle. 4. Click on the Identify SEM button in ServiceLink. This causes the smart switch indicator lights to blink. 3. See the "Smart Switch Part Number, Function, and ID Number" table in Specifications 400 to cross-reference the smart switch part number with the smart switch function. Compare this with the smart switches that were expected based on what features the Bulkhead Module was pro- grammed to use. 5. Based on the descriptions of the switches con- nected to the SEM, look for the smart switch that is connected to the SEM, but has an indicator light that is not blinking.
6. Once the affected smart switch is identified, troubleshoot the switch and check the wiring for a short circuit. The Switch Controlled Option Does Not Work 4. Determine which smart switch is missing or not being correctly identified. Duplicate Smart Switch Fault The Duplicate Smart Switch fault indicates that there are two or more identical smart switches connected to either the BHM or SEM smart switch ports. When a smart switch controlled option does not work when the smart switch is activated, the problem is likely due to one of the conditions described in Table 3 . Determine which smart switches the vehicle is pro- grammed to use.
See the Features screen in Ser- viceLink to determine which smart switches the ve- hicle is programmed to use. For instructions, see "Determining Which Smart Switches the Vehicle is Programmed to Use" in this subject. If a function does not work and there are no active smart switch fault codes, then the following proce- dure will help determine if the smart switch itself or its wiring is the cause of the problem. If smart switch fault code(s) are active, troubleshoot them first. The switch function that is duplicated will be two or more smart switch ports that have the same smart switch ID number shown in the applicable template. The duplicate switch must be disconnected.
See the ServiceLink User’s Guide under "Templates" for in- structions on using DataLink monitor templates. Smart Switch VBAT Short to Ground Fault To determine if the smart switch or its wiring is the cause of the multiplexed function not working, see Table 4 . The Smart Switch VBAT Short to Ground fault indi- cates a smart switch indicator and/or backlight drive circuit is overloaded. Only smart switches connected to a SEM will report this fault. Use the following steps to troubleshoot this fault. 1. Access ServiceLink to determine which smart switches are connected specifically to the SEM. 2. Click on the Switch Expansion Module icon on the left-side list of the ECUs. 3.
Click on the Smart Switch tab. A list of all smart switches that are connected to the SEM will be displayed. Business Class M2 Workshop Manual, Supplement 22, September 2012 300/4