Smart Switches 54.14 Troubleshooting Smart Switch Controlled Option Faults Problem Description Hardware problems Main VBAT fuse that supplies the output pin is open. BHM, CHM, or EXM output driver circuit is overloaded; too much current will cause the output to shut off. Output problems The output device is faulty. For example, the suspension dump AMU/AAVA solenoid valve is faulty. Faulty BHM, CHM, or EXM output driver (internal BHM, CHM, or EXM problem). The output device wiring is faulty. Output is not wired to the correct output pin. If the output is connected to the CHM, there are possible J1939 communication problems between the BHM and CHM.
If the output is connected to an EXM, there are possible J1939 communication problems between the BHM and EXM. Input problems Faulty smart switch. Faulty smart switch wiring. Other input conditions for the function to activate are not met. For example, the BHM does not sense that the park brake is set in order to activate the suspension dump valve. J1939 communication problems exist between the optional SEM and the BHM. Software problems The reference parameter is not compatible with vehicle options. The reference parameter has errors. Table 3, Smart Switch Controlled Option Faults Step Test Procedure Test Result Action Smart Switch Troubleshooting 1 Are any smart switch faults active?
Yes Troubleshoot faults as outlined in this subject. No Go to step 2 . Business Class M2 Workshop Manual, Supplement 22, September 2012 300/5