Smart Switches 54.14 Troubleshooting Smart Switch Troubleshooting Step Test Procedure Test Result Action 2 Observe the smart switch indicator (if equipped) while attempting to operate the function with the switch. Blinks steady The function interlocks were met, but the BHM does not sense that the function actually engaged. For example, if a function uses an AMU/AAVA solenoid, the BHM may not be sensing that the function engaged through the AMU or air pressure switch. This could be caused by the AMU/AAVA solenoid not switching, a defective pressure switch, or a wiring fault. NOTE: If the switch does not have an indicator light, go to step 3 .
This does not indicate a problem with the smart switch. On, then quickly off Some other condition is not met in order for the function to work. For example, if the function requires that the park brake be set in order for the function to operate, and the park brake is not set, then the function will not work. This does not indicate a problem with the smart switch. Switch does not have indicator Go to step 3 . Off Go to step 3 . 3 Using ServiceLink, access the BHM Features screen. Yes Go to step 4 . Is there a reference parameter listed for the function, and does it indicate the use of a smart switch? No The reference parameter for the function is not loaded into the BHM.
Load the correct reference parameter using ServiceLink. 4 Find the part number on the smart switch for the function that is not working. Using the "Smart Switch Part Number, Function, and ID Number" table in Specifications 400 , find the ID Number that corresponds to the part number of the switch. Yes The problem is not with the smart switch or its wiring. The problem is either with the output to the function, or possibly a reference parameter problem. In ServiceLink, open the applicable smart switch template (either for the BHM, or SEM). Locate the column that has the smart switch ID that matches the ID Number in "Smart Switch Part Number, Function, and ID Number" table in Specifications 400 .
While observing the input or position status on the template, operate the switch through each position. There should be a change in either the voltage input, or position (depending on the template). No Go to step 5 . Is there a change in switch position reflected in the template? Business Class M2 Workshop Manual, Supplement 22, September 2012 300/6