Freightliner — Freightliner Business Class M2 Workshop Manual

Switch Expansion Module 54.16 Fault Code Information SEM J1939 Source Address Claiming Scheme 128 must now claim 129, the SEM that used to claim 129 must now claim 130. A Switch Expansion Module (SEM) on the J1939 datalink claims a J1939 source address. The source address (SA) identifies the module and can be viewed using ServiceLink ® . See Table 1 for a list of the SEM source addresses. Invalid SEM If a problem occurs while flashing the application code on an SEM, the SEM may not be able to claim one of the source addresses in Table 1 . The SEM will appear in ServiceLink screens at source address 133 and with an icon labeled Invalid SEM (Unre- sponsive) .

It will not report any make, model, or software ID. In this case, the technician can still ac- cess the Flashing tab and attempt to flash the SEM to recover it. Source Address SEM Number SEM J1939 Source Addresses 128 SEM #1 129 SEM #2 Locating the Correct SEM to Troubleshoot Table 1, SEM J1939 Source Addresses 130 SEM #3 Switch Expansion Modules on a vehicle are num- bered SEM #1 through SEM #3 depending on the serial number of the SEM. The SEM with the lowest serial number, which is printed on the SEM housing, attempts to claim the lowest SEM source address, 128. Each additional SEM then claims a source ad- dress in similar fashion from low to high.

The SEM with the next-highest serial number claims the next- highest source address, 129, and so on until all SEMs have claimed a source address. To assist the technician in determining the specific SEM a given smart switch is connected to, Service- Link has a Smart Switches tab located under the SEM icon. There the technician will find an Identify SEM button that can be used to briefly flash the indi- cator lights of a bank of smart switches connected to a specific SEM. This allows the technician to locate the correct SEM for troubleshooting smart switches. NOTE:

Although the Bulkhead Module (BHM) supports up to three Switch Expansion Modules, the SEM mounting bracket on the Business Class ® M2 vehicle is designed for mounting only one SEM. Removing an SEM 1. Connect to the vehicle in ServiceLink and take note of the icons that appear for the SEMs con- nected to the vehicle. Once an SEM is installed and claims an address, it stores that as a preferred source address. Every time the vehicle is turned on after that, the SEM will at- tempt to reuse that preferred source address.

This way, each SEM should appear in ServiceLink as the same SEM number (SEM #1 through SEM #3) each time ServiceLink is connected, regardless of whether an SEM is removed or whether the physical locations of the SEMs on the vehicle have changed. The only exception is when an SEM with a lower serial num- ber is added. 2. Remove the SEM. 3. Reconnect to the vehicle in ServiceLink and take note of the icons that appear for the SEMs con- nected to the vehicle. 4. The icon for the removed SEM should be gone and none of the other SEMs still on the vehicle should change their order.

For example, if there are three SEMs on a vehicle, appearing in Ser- viceLink as SEM #1, SEM #2, and SEM #3 and the second SEM is removed, on reconnecting to the vehicle in ServiceLink the icons for SEM #1 and SEM #3 still appear and the icon for SEM #2 is gone. If a new SEM is installed that has a serial number lower than those already on the vehicle, the new SEM will claim the lowest source address, 128, and bump up the source addresses of the other SEMs. The SEM that used to claim the source address of Business Class M2 Workshop Manual, Supplement 10, September 2006 300/1