Freightliner — Freightliner Business Class M2 Workshop Manual

Switch Expansion Module 54.16 Fault Code Information Fault Codes See Table 3 for the failure mode identifiers (FMI) for J1939 datalink protocols. NOTE: For troubleshooting procedures, see Section 54.14, Subject 300 . See Table 2 for J1939 suspect parameter numbers (SPN) for Switch Expansion Module source ad- dresses (SA) 128 through 130.

J1939 Suspect Parameter Numbers for Switch Expansion Module Source Addresses 128 Through 130 SPN J1939 Description Possible FMI 2033 No CAN communication from BHM 19 6914 Smart Switch VBatt Short to Ground 04 Table 2, J1939 Suspect Parameter Numbers for Switch Expansion Module Source Addresses 128 Through 130 FMI J1939 Description Failure Mode Identifiers 19 Received network data in error 04 Voltage below normal or shorted low Table 3, Failure Mode Identifiers Business Class M2 Workshop Manual, Supplement 10, September 2006 300/2