Power Distribution Module 54.17 Troubleshooting Troubleshooting MEGA Fuses MEGA Fuses Main PDM 1 MEGA fuses must be measured using a voltmeter when in the circuit or with an ohm meter when out of the circuit to determine if they are open. There is no visual method of determining continuity. See Fig. 1 . Starter Main PDM 2 Alternator Trailer PDM + Powertrain PDM In 2008, the type of MEGA fuses changed from Bussman to Littelfuse. The Littelfuse is staked and addresses the intermittently open circuit fault that may occur with the Bussman fuse. When MEGA fuses are replaced, be certain that stainless steel nuts and washers are used.
Cover the connections in the battery box liberally with dielectric grease. PNDB Batteries Battery Disconnect Switch Each powernet distribution box (PNDB) on the ve- hicle provides up to 4 low amperage circuits (30 amp and less), and up to three high amperage circuits through midi fuses. The fuses are located behind a cover on the face of the PNDB. On vehicles equipped with a cab load disconnect switch (CLDS), the high amperage circuits are switched on and off with the CLDS. The low amperage circuits are al- ways live. Vehicles may have one or two PNDBs and both are connected to the same CLDS. 11/29/2010 f545711 Fig.
1, Typical EPA07 and Earlier In-Battery Box MEGA Fuse Schematic on when the switch is off or no LED when the switch is on also indicates an error condition. To test for open fuses, use conventional trouble- shooting methods. The LED’s in the PNDB and switch are not affected by open fuses or the circuits they connect. NOTE: See Table 1 to troubleshoot a switched PNDB system When the CLDS is in the on position, an LED on the switch, and another on the PNDB, will be illuminated. When there is an error condition with the PNDB sys- tem, the LED on the PNDB and CLDS may flash. A flashing LED indicates an error.
An LED that remains PNDB and CLDS Troubleshooting Step Test Procedure Test Result Action Check the power cables on the PNDB for proper torque. Open the cover and inspect the MIDI fuse fastener torque and for discoloration caused by excessive heat. Loose fasteners or heat discoloration. Determine if the fasteners can be properly torqued or if the PNDB needs replacement. Repair or replace as required. 1 All OK Go to step 2. Constant Repeating Flashing Pattern Troubleshoot and repair any wiring faults on circuits 425D, 425F, or circuit 425G between the CLDS and the PNDB. If there is no wiring fault, replace the CLDS.
Does the LED on the PNDB flash in a constant pattern when the CLDS is switched to the OFF or ON position or does the LED on the PNDB just randomly flicker? 2 Random flickering. Replace the PNDB. No Go to step 3. Business Class M2 Workshop Manual, Supplement 20, September 2011 300/1