Freightliner — Freightliner Business Class M2 Workshop Manual

Power Distribution Module 54.17 Troubleshooting PNDB and CLDS Troubleshooting Step Test Procedure Test Result Action Measure for ground on PNDB connector 1, pins 1 and 6. If either of these pins are not populated with a wire disregard measuring the unpopulated pin. Measure the voltage on PNDB connector X1, pin 4. If pin 4 is at about 11 volts then troubleshoot and repair for a wiring fault in circuits 425D, 425F, 425G between the CLDS and the PNDB and for a open or short circuit in the CLDS. If there is no wiring or switch fault, replace the PNDB. 3 Yes Is ground present in the wiring harness supplying these pins? No Repair an open ground circuit to the PNDB.

Table 1, PNDB and CLDS Troubleshooting See Fig. 2 , Fig. 3 , Fig. 4 , and Fig. 5 for illustrations of the connectors with pin identification. 3 1 See Table 2 for primary PNDB and CLDS connector and pin functions. NOTE: PNDB connector X2 is not part of the switching and control system. See Table 3 for information on the function of PNDB connector X2. 4 2 11/29/2010 f545708 1 4 Fig. 4, Wire Insertion View of CLDS Connector X1 1 3 6 12/15/2010 f545718 Fig. 2, Wire Insertion View of PNDB Connector X1 1 11/29/2010 f545709 3 Fig. 5, Wire Insertion View of CLDS Connector X2 2 3 11/29/2010 f545710 4 Fig.

3, Wire Insertion View of PNDB Connector X2 Business Class M2 Workshop Manual, Supplement 20, September 2011 300/2