Power Distribution Module 54.17 Troubleshooting Primary PNDB and CLDS Connector and Pin Functions Device Connector, Pin Voltage Function X1, 1 0 Ground X1, 2 0 Off Signal – Always at ground. Primary PNDB X1, 3 0 ON LED Indicator PNDB drives this low when the switch is on. X1, 4 11 On Signal – Approximately 11 volts. X1, 5 11 ON 0 OFF Control Signal – Approximately 11 volts when CLDS is on. At ground when off. X1, 6 0 Not used or ground circuit connecting to aux PNDB. X1, 1 11 On Signal – Approximately 11 volts. X1, 2 11 ON 0 OFF Control Signal – Approximately 11 volts. when CLDS is on. At ground when off. CLDS X1, 3 0 ON LED Indicator PNDB drives this low when switch is on.
X1, 4 0 Off Signal – Always at ground. X2, 1 11 ON 0 OFF Control Signal – Approximately 11 volts when CLDS is on. At ground when off. X2, 2 0 Off Signal – Always at ground. X2, 3 0 ON LED Indicator PNDB drives this low when the switch is on. X1, 1 0 Ground X1, 2 0 Off Signal – Always at ground. Auxiliary PNDB X1, 3 0 ON LED Indicator PNDB drives this low when the switch is on. X1, 4 X Not used. X1, 5 11 ON 0 OFF Control Signal – At approximately 11 volts when CLDS is on. At ground when off. X1, 6 0 Not used, or ground. Table 2, PNDB and CLDS Connector and Pin Functions See Fig. 6 for a schematic of the dual PNDB system with the cab load disconnect switch option.
Business Class M2 Workshop Manual, Supplement 20, September 2011 300/3