Rear and Turn Signal Lighting Systems 54.28 Troubleshooting Stop Lights Fault Conditions Description of Fault Action Taken by BHM Left stop light wiring is shorted. BHM may transmit a J1939 and/or a J1708 fault message. Right stop light wiring is shorted. BHM may transmit a J1939 and/or a J1708 fault message. Table 2, Stop Lights Fault Conditions Stop Lights Switch Tests for a Vehicle With Air Brakes NOTE: If any test fails, the Pressure Switch Module A is defective and must be replaced. Test Conditions Test Point Good Result If Test Fails: Stop Light Ground Circuit Key off, engine off. Resistance Check: Less than 1 ohm. Check ground circuit wiring. Battery disconnected.
Measured between pin D (harness side) and the negative battery terminal. Pressure switch "A" 6-way connector disconnected. Stop Light Switch Diode Key off, engine off. Resistance Check (or diode test if meter is capable): With the leads connected one way, the meter should read resistance (value not important). When the leads are reversed, the reading should be infinite or OL. Faulty Pressure Switch "A." Applies to part number 12-18205- XXX. For all other part numbers, skip this test. Drain air tanks. Pressure switch "A" 6-way connector disconnected. Measured between pin C and D (switch side). Then reverse test leads and check again. NOTE:
If the result is 0 ohms both ways, either the diode is shorted or the pressure switch is stuck closed. If the result was OL both ways, the diode is open. Business Class M2 Workshop Manual, Supplement 22, September 2012 300/2