Freightliner — Freightliner Business Class M2 Workshop Manual

Rear and Turn Signal Lighting Systems 54.28 Troubleshooting Stop Lights Switch Tests for a Vehicle With Air Brakes NOTE: If any test fails, the Pressure Switch Module A is defective and must be replaced. Test Conditions Test Point Good Result If Test Fails: Stop Light Switch Key off, engine off. Pressure switch "A" 6-way connector disconnected. Resistance Check: Less than 1 ohm (test leads both ways). Faulty Pressure Switch "A." Measured between pins C and D (switch side). Then reverse test leads and check again. NOTE: If the resistance is more than 1 ohm either way, then the stop light switch is not closing between 2 and 5 psi (13 and 34 kPa). Drain air tanks.

Disconnect one of the APP ports on the face of the module and connect a regulated air supply setup to the port. Using the setup, close Valve "A" and Valve "B." Back the regulator screw off so that the downstream pressure is zero. Connect shop air to the test apparatus. Open Valve "A." Apply 10 psi (69 kPa) to the APP port by adjusting the pressure regulator. This should cause the stop light pressure switch to close. Table 3, Stop Lights Switch Tests for a Vehicle With Air Brakes Backup Lights Fault Conditions Input and Output Conditions See Table 5 for the backup lights system conditions that will create a fault.

The reference parameters that program the BHM determine whether a fault code is broadcast. Therefore, even if the BHM detects a fault, a fault code may not be transmitted. If the BHM is programmed to transmit fault codes, they can be viewed through ServiceLink. Fault messages may be transmitted on the J1939 and/or the J1708 datalinks until the ignition switch is turned off. See Table 4 for the BHM responses to the backup lights input/output conditions. Backup Lights Input/Output Conditions Ignition Switch Transmission Status Backup Lights/Alarm * Inputs to BHM Output from BHM On a vehicle with an automatic transmission, the BHM has additional J1939 fault messages that may be broadcast.

Any J1939 fault message may be transmitted until the ignition switch is turned off. See Table 6 . On/Acc Reverse On On/Acc Not Reverse Off Off Reverse Off Off Not Reverse Off * Via J1939 message to the CHM Table 4, Backup Lights Input/Output Conditions Business Class M2 Workshop Manual, Supplement 22, September 2012 300/3