Body Builder Lighting Interfaces 54.35 Troubleshooting Electrical Troubleshooting Option Description of Fault Possible Cause High Current No outputs MEGA ® Fuse that supplies the PDM is open or missing. High Current No operation on a single output PDM components are inoperable. Check the PDM fuse (blown) and relay (stuck) for that output. Low Current, Additional Marker Lights No operation on a single output CHM may have disabled the output due to an overloaded circuit. Make sure that the collective load does not surpass the maximum current capacity for that circuit. All Intermittent or no operation at all outputs Loss of connection.
Check electrical connectors to make sure they are properly connected. For the high-current interface, check the ground connection. All Intermittent or no operation on a single output Trace the suspect circuit and look for a loose terminal connection or damaged wire. Additional Marker Lights Intermittent or no operation Check to see if the inline fuse is open (blown). Check the additional marker light connection point for proper installation. Table 1, Electrical Troubleshooting Business Class M2 Workshop Manual, Supplement 10, September 2006 300/1