Chassis Electrical Control Systems 54.40 Interaxle Lock Troubleshooting Interaxle Lock For electrical troubleshooting of the interaxle lock, see Table 1 . Interaxle Lock Troubleshooting Symptom Possible Cause Check For Blinking indicator on the interaxle lock switch. No feedback. Damaged feedback circuit. Interaxle lock may engage then drop out, or not engage at all. Insufficient air pressure. If air pressure gauge indicates sufficient pressure, there may be a kink or restriction in the air lines. Defective air management unit (AMU)/auxiliary air valve assembly (AAVA) solenoid. Remove the air line from the forward rear axle differential and turn on the switch.
If no air, replace the solenoid. Wiring fault in the circuit feedback switch. Inspect grounds. Clean or repair as needed. Defective electrical connection to the AMU/AAVA solenoid. Inspect connector and pins. Straighten bent pins and make sure that electrical connections are properly seated. Table 1, Interaxle Lock Troubleshooting Business Class M2 Workshop Manual, Supplement 22, September 2012 300/1