Chassis Electrical Control Systems 54.40 Axle Shift Troubleshooting Axle Shift For electrical troubleshooting of the axle shift, see Table 1 . Axle Shift Troubleshooting Symptom Possible Cause Check For Blinking indicator on the axle shift switch. No feedback. Damaged feedback circuit. Axle high range may engage then drop out, or not engage at all. Insufficient air pressure. If air pressure gauge indicates sufficient pressure, there may be a kink or restriction in the air lines. Defective air management unit (AMU)/auxiliary air valve assembly (AAVA) solenoid. Remove the air line from the gear housing and set switch to high range position.
If air is not heard from the air line, replace the solenoid. The electrical connection to the AMU/AAVA solenoid is defective. Inspect connector and pins. Straighten bent pins and make sure that electrical connections are properly seated. Wiring fault in the axle position feedback circuit. For multiplexed controls, a ground signal from axle switch circuit indicates low gear range to the Chassis Module (CHM). Make sure that the axle switch circuit is not shorted to ground. Defective ground to solenoid or feedback switch. Inspect grounds. Clean or repair as needed. Table 1, Axle Shift Troubleshooting Business Class M2 Workshop Manual, Supplement 22, September 2012 310/1