Chassis Electrical Control Systems 54.40 Fifth Wheel Slide Troubleshooting Fifth Wheel Slide For electrical troubleshooting of the fifth wheel slide, see Table 1 . Fifth Wheel Slide Troubleshooting Symptom Possible Cause Check For Blinking indicator on the fifth wheel slide switch. No feedback. Damaged feedback circuit. Fifth wheel slide may engage then drop out, or not engage at all. Insufficient air pressure. If air pressure gauge indicates sufficient pressure, there may be a kink or restriction in the air lines. Defective air management unit (AMU)/auxiliary air valve assembly (AAVA) solenoid. Remove the air line from the fifth wheel slide release cylinder and turn on the switch.

If no air, replace the solenoid. Wiring fault in the feedback switch circuit. Inspect grounds. Clean or repair as needed. The electrical connection to the AMU/AAVA solenoid is defective. Inspect connector and pins. Straighten bent pins and make sure that electrical connections are properly seated. Table 1, Fifth Wheel Slide Troubleshooting Business Class M2 Workshop Manual, Supplement 22, September 2012 330/1